  350W
JNP-350P |
|
| |
|
|
|
350 Watts output
Support both 20pin and ATX12V 2.0 24pin motherboards
20+4 main connector -- 20-pin and 24-pin dual use main connector
High quality 80mm fan design.
Dual S-ATA power connector included
Passive Power Factor Correction (PFC)
Extra long cables to support server (full) tower cases.
Fan Speed Monitor connector (3-pin)
Easy Connect Peripheral power connectors -- now removing the
power connector from HD or CD ROM is easy, simply sqeeze and pull
Automatic fan speed control (A.F.C) or smart fan
I/O Switch for manual shut-down
Over Voltage Protection
Over Power Protection
Over Heat Protection Short
Circuit Protection
Built in Quad protection
|
 |
|
|
|
| Dimension |
|
|
1X 20+4 main connector
Standard ATX
1x PCI Express Connector
6X Peripheral Power Connector
1X 4-pin ATX12V Power Connector
2X Floppy Drive Power Connector
1X 3-pin Fan Speed Monitor
2x S-ATA
|
|
Dimension |
| Unit Size |
150mmx140mmx86mm |
| Net Weight |
1.9KGS |
 |
|
|
Maximum Power |
350W |
| |
I/O switch, 115/230 switch |
Special Connectors |
1 x 20+4 pin M/B; 1 x
ATX 12V 4 pin, 6 x peripheral connectors, 2 x floppy drive power connector,
2 SATA connector, 1 x 3 pin fan monitor connector |
| |
Transient Response |
No define in the spec |
P.G. Signal |
TTL compatible. Signal goes high 100-500ms |
Over Voltage Protection recycle AC to reset |
The +5V/+12V1/+12V2/+3.3V DC output are protected against
the over voltage condition. Maximum value can’t be over 7V at
5V terminal, 15.6V at 12V1 & 12V2, 4.5V at 3.3V |
|
|
| Unit Size |
150mmx140mmx86mm |
| Net Weight |
1.95KGS |
|
|
Input Voltage |
115/230Vac (Switch select) |
Input Frequency |
47-63Hz |
Input Surge Current |
Less then the ratings of it’s critical components (Including
bulk rectifiers. Fuses and surge limiting device). |
Input Current |
8.0A at 115Vac; 4.0A at 230Vac |
Hold-up Time |
>16ms at full load at 115 Vac |
Efficiency |
Typical 65% at full load |
EMI/RFI |
FCC Part 15 Class B & CISPR 22 Class B |
|
|
| |
+3.3V* |
+5Vs |
+12V1 |
+12V2 |
+5V |
-12v |
|
Max load |
20A |
0.0A |
10.0A |
13.0A |
20.0A |
0.8A |
|
Min. Load |
0.3A |
2.0A |
1.0A |
1A |
1.5A |
0A |
|
Load Reg. |
+5% ~ -5% |
+5% ~ -5% |
+5% ~ -5% |
+5% ~ -5% |
+5% ~ -5% |
+10%~ -10% |
|
Ripple Peak-to-
Peak Max. |
70mV |
70mV |
200mV |
200mV |
100mV |
200mV |
|
Ripple&Noise
Peak-to-Peak Max. |
100 mV |
100 mV |
120 mV |
120 mV |
70mV |
120mV |
|
| *
+5V, +12V1, 12V2 AND +3.3V max load: 328.9 Watts
* +5V and +3.3V Combined output: 150 Watts |
|
|
Operating Tem. |
0°C to 50°C |
Operating Alt. |
0-8000feet |
Non-Operating Vibration |
Sweep and resonance search for each of X,Y,Z axis at the sweep.
Refer the standard IEC 60086-2-6, Rate of 1 / octave / Min |
|
|
|
|
|
|
|
|
MTBF |
> 100,000 hours at 75% load and 25°C
ambient conditions |
|
|
|
|
|
|
|
|
Safety Approval |
UL(CUL) / TUV / Nemko / CB |
|
| |
| oV |
25 |
30 |
35 |
40 |
45 |
55 |
60 |
65 |
70 |
75 |
80 |
85 |
90 |
|
|
| V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RPM |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| db |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|